10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply

Product Details
Customization: Available
Voltage Type: DC Voltage
Input Signal Type: DC Voltage Transmitter
Still deciding? Get samples of US$ 28/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
27
Year of Establishment
2002-09-10
  • 10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply
  • 10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply
  • 10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply
  • 10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply
  • 10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply
  • 10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply
Find Similar Products

Basic Info.

Model NO.
WHBXXXXH-2W
Output Signal Type
Digital Output
Phase
--
Display Type
--
Accuracy Grade
0.5G
IP Rating
IP20
Certification
Ce, RoHS, ISO9001
Customized
Customized
Input
3.3, 5, 9, 12, 15, 24 VDC
Output
3.3, 5, 9, 12, 15 VDC and Adjustable
Isolation Voltage
10000VDC
Isolation Way
Magnetoelectric
Power
0.25W-2W
Packaging Way
SIP12
Payment Way
Paypal, Western Union, T/T
Shipping Way
DHL, FedEx, TNT etc
Warranty
2 Years
Lead Time
3-4days
Transport Package
Color Box
Specification
10g
Trademark
SunYuan SZ
Origin
China
HS Code
8504401990
Production Capacity
50000PCS Per Month

Product Description

Electric Medical Instrumentation10kv High Isolation 1W 2W DC-DC Power Converter

Product Description
 
The newest WHB series DC/DC Converter developed by SunYuan, It uses wide isulation distance and new isolation material design and comply with the relevant safety regulations of the external RS232/RS485 bus control communication interface in the national electric industry DL/T 614-2007 multi-function energy meter protocol standard, It is a high-isolation & anti-pulse electrostatic dc-dc converter for the intelligent control of the instrumentation equipment bus Ethernet interface commonly used in the electric power medical industry such as power load management terminal, multi-function electric energy meter, blood analyzer, life monitor etc. The SIP12Pin high integration and small size package technology enables the module to have self-recovery overload short-circuit protection and regulated output function.
 
After the electric medical equipment is added to the WHB series dc dc converter, the safety barrier isolation voltage value of the external bus Ethernet (RJ45/RS232/RS485) interface terminal of the instrumentation equipment reaches 10KVDC high isolation and 8KVAC anti pulse group electrostatic protection due to the high isolation between the input and output terminals of the module power supply. Therefore, the WHB series of high isolation dc dc converter can make the equipment and equipment resistant to EMC upgrade and can pass the safety inspection of the electric medical industry.
Model&Definision:
10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply

Dimensions and pin function description:

(Remarks:The 10 feet of the product are the non-functional feet that are suspended inside, which can be used to strengthen the mechanical strength of the module and PCB board.)

Input Voltage                    
3.3, 5, 9, 12, 15, 24 VDC
Output Voltage                                                                 
3.3, 5, 9, 12, 15 VDC 
Remarks:
For other non-standard output voltage value specifications, please contact Sunyuan Technology Co., Ltd.
Electrical Characteristics
The following data are measured at TA=25° C, nominal input voltage, and rated output current except for special instructions.
Input Characteristics
Voltage range                                                         +/-10% Nominal value
Internal filtering                                                      Ceramic capacitors
Isolation Characteristics
Rated voltage                                                         10,000 VDC(about 8000VAC)
Leakage current                                                    1 mA
resistance                                                               109  Ohm
capacitance                                                             60 pF type.
Ouput Characteristics
Antistatic rating                                                        ≥8000VAC pulse goup
Voltage accuracy                                                     Output voltage fluctuation range is +/-2% of nominal             value(load variation range 0-100%)
( 20 MHz BW) Ripple and noise                           <50 mVp-p,max
Sustainable short circuit time                               Output with self-recovery overload short circuit protection
Linear voltage calibration                                       +/- 0.5 % max,(3.3 VDC output +/- 1 % max )
Load voltage calibration                                         +/- 0.5 % typ, +/- 1 % max, (No load to full load) 
Temperature Coefficient                                         +/- 0.02 % / °C
External filter capacitor                                           Suggest Co ≤4.7uF,otherwise it will broken easily
General Characteristics
effectiveness                                                           60% to 80%
On-off level                                                               60KHz,type.
Environmental Characteristics
Working temperature (environment)                     - 40° C to + 85° C
storage temperature                                                - 55 °C to + 125 °C
Lower the fixed value                                              See temperature characteristic curve
temperature                                                              ≤ 90 %,Uncompressed
cooling method                                                       Natural air cooling
Shape Characteristics
SIP (single row in line) package size                 33.0 x 10.5 x 15.5 mm
1.3 x 0.413 x 0.61 inch
Weight                                                                      6g~10g
Shell Material                                                          Non-conductive flame retardant black plastic
WHB Series product models selection  (The following data is the measured value of the product after 8 hours of continuous full load aging.)


 
Model number Input voltage Vin(VDC) Input current
No load (mA)
Input Current
Full load (mA)
Output voltage Vout(VDC ) Output current (max.mA) Full load efficiency (%TYPE)
WHB0503H-1W 5 20 317 3.3 303 63
WHB0505H-1W 5 30 300 5 200 66
WHB0512H-1W 5 30 260 12 83 76
WHB0515H-1W 5 32 255 15 67 78
WHB1205H-1W 12 14 126 5 200 66
WHB1209H-1W 12 15 120 9 111 69
WHB1212H-1W 12 15 110 12 83 75
WHB1215H-1W 12 16 115 15 67 72
WHB2405H-1W 24 8 61 5 200 68
WHB2409H-1W 24 9 58 9 111 72
WHB2412H-1W 24 12 70 12 83 60
WHB2415H-1W 24 9 60 15 67 69
WHB0505H-2W 5 55 580 5 400 68
WHB0512H-2W 5 35 445 12 167 89
WHB0515H-2W 5 40 495 12 167 80
WHB1205H-2W 12 30 250 5 400 66
WHB1209H-2W 12 28 216 9 222 77
WHB1212H-2W 12 25 198 12 167 84
WHB1215H-2W 12 27 215 15 133 77
WHB2405H-2W 24 8 119 5 400 69
WHB2409H-2W 24 8 103 9 222 80
WHB2412H-2W 24 10 100 12 167 83
WHB2415H-2W 24 9 105 15 134 79
10kv High Isolation Anti-Static Electric Medical Instrumentation DC Power Supply
Remark: The output efficiency of the output voltage value adjustable product is calculated according to the actual value.

Temperature characteristic curve:



Product pressure test notes and test methods:
1,As shown in Figure 1: According to the product isolation voltage specification and set the rated high voltage value, please pay attention to personal safety when testing, beware of electric shock!!!
Test conditions: room temperature TA = 25 ° C, humidity <75%
2,The pressure test operator must wear rubber-insulated gloves and a rubber insulation pad under the seat to prevent high-voltage electric shock.
3,The pressure tester instrument must be grounded reliably and should not be tested in high temperature, humid and dusty environments.
4,The pressure tester must ensure that the high voltage output is "0" and "reset" when connecting the measured object.
5,Do not touch the test object, test line or high voltage output when the instrument is in the startup state or before the test high voltage is released.
6,The product pressure test test method as shown in Figure 1: shorting the input and output pins respectively, and adding isolation voltage between the input and output terminals (DC or AC peak, according to the isolation voltage given by the product), test 1 minute.
7,According to the standard of pressure test, the withstand voltage value is gradually increased from 0, and it is adjusted to the set maximum and maintained at the highest withstand voltage for one minute.
8,The Pressure test itself is a destructive test. The fewer times you should do the better, if the customer needs to test multiple times, the general requirements are: the first time according to the value of the specification, the next time should be correspondingly reduced test the voltage, otherwise the product will be damaged during multiple tests.

Introduction of SunYuan's newest DC-DC Conveters:

1.GRS Series 1-3W Small Size 6KV high Isolation Type DC-DC power Modul
2.GRC Series 5V, 12V, 24V Input Signal to 250V, 300V, 400V Output Signal Isolated High Voltage dc/dc converter
3.GRE Series 6kvd Double Loop Isolated Output High Voltage DC/DC Power Module 
4.WHB series:10KV high isolation antistatic DC-DC module power


Introduction of SunYuan Technology normal used DC-DC Converters
1)The special isolation dc-dc converters for entrance guard swipe machine: IB0505S-1W; IB0512S-2W; IB0305S-W5
IB/VB series VBXXXXS-1W/2W products, the isolation voltage is 1KVAC between input and output, strong anti-interference ability. Constant voltage input and Regulated voltage output (nominal error < 2%), the output has self recovery overload short circuit protection function. Standard SIP 7 Pin/DIP 14 Pin flame retardant package.
Detailed technical information:

https://sunyuan.en.made-in-china.com/product/MXSmnjdunxhV/China-2W-Fixed-Input-Regulated-Output-DC-DC-Converter-IB-X-X-X-X-.html


2)RS485/422/232/CAN bus interface isolation dc converter: B0505S-1W; B0509S-W1; B0305S-W5
B series BXXXXS-W5/1W products, the isolation voltage is 1KVAC between input and output. Fixed voltage input & non-regulated output (nominal error < 5%) standard SIP 4 Pin / DIP 8 Pin low cost, small size flame retardant package. It is widely used in computer 232/485, remote communication and intelligent control.
Detailed technical information:

https://sunyuan.en.made-in-china.com/product/BvnEsXucZJhK/China-Low-Cost-Small-Size-1kv-Isolation-Fixed-Voltage-Input-Unregulated-3V-3-3V-5V-12V-24V-0-1-1W-DC-DC-Converter.html


(3)Distribution load tester, power management terminal 485 interface anti-surge anti-static high isolation dc-dc converter module: E/F/G/H/WRF/WRE/VDH series
We designed and produced a series of high isolation dc-dc converter module with anti-surge and anti-static interface RS485 according to the requirements of electronic industry instrument manufacturers such as distribution load tester and power management terminal and basis of the national electronic industry standard (DL) DL/T614-1997 and (DL) DL/T614-2007. The DC-DC converter module used in these electronic industries has the following functions: anti-surge 4KVAC/6KVAC high isolation, 8KV anti-static, output voltage stabilization (2% accuracy), also with self-restoring overload short circuit protection output and so on. Common product specifications have: 3KVAC/6KVAC high isolation, output power 0.2W/0.5W/1W/2W, 5VDC/9VDC/12VDC/15VDC single voltage output, +5VDC/+9VDC/+12VDC positive and negative double voltage output and ++ 5VDC/++ 9VDC/++ 12VDC/++ 15VDC double isolated double voltage output.
Detailed technical information:

https://sunyuan.en.made-in-china.com/product/xvZEkjnVLXWO/China-Low-Cost-Can-Bus-Port-Signal-Isolation-Module.html
Detailed technical information:
https://sunyuan.en.made-in-china.com/product/JBfxtpCzOihj/China-DC-DC-Converter.html



(4) The power supply automation equipment DC/DC double isolation circuit dc-dc converter modules: D050512S-1W; D240505S-2W; D050505S-1W
D S series constant voltage input, 1KVAC double isolation double circuit unsteady voltage output DC-DC Converter module is mainly used in instruments, transducers, CNC equipment and other occasions that require multiple distributed power isolation. Standard SIP 7 Pin/DIP 14 Pin flame retardant package.
Detailed technical information:

https://sunyuan.en.made-in-china.com/product/FBDmvdZHijhI/China-0-1-2W-Small-Size-Isolated-24V-to-12V-DC-DC-Voltage-Converter.html

(5)High voltage output dc-dc converter module for medical instrument: GRBxxxxD-xW
9-18VDC, 18-6VDC (2:1) wide voltage input, 100VDC, 120VDC, 150VDC high voltage output, with high power density. It is widely used in medical instrument manufacturing industry.
Detailed technical information:

https://sunyuan.en.made-in-china.com/product/FZBEbeJvLGVk/China-100V-110V-220VDC-High-Voltage-Boost-DC-DC-Converter-Power-Modules.html

(6)Isolated transmitter two wire loop sampling and distribution special dc-dc converter: BHK series
It is specially designed for isolating power supply and distribution between pressure, displacement, temperature and humidity sensors and transmitters. The products are characterized by high isolation, small size and ultra-low power consumption. They are widely used in CNC machine tools, instruments, industrial control intelligent and other fields.
Detailed technical information:

https://sunyuan.en.made-in-china.com/product/TKZmLzXbhgct/China-Isolated-DC-DC-Converter-Module-with-SIP-Package.html

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier