6KVD Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc equipments : GRE Series
Product features:
1. Low cost and small size SIP 12PIN packaging meets UL94V-0 standard of flame retardant packaging.
2.There is 6KVD isolation between the input and output of this module,And also 6KV isolation between the output loop one and loop two.
3.2: 1 DC wide voltage input range, isolated regulated DC high voltage output .
4.Output voltage: 50VDC ~ 400VDC voltage value is for you optional.
5.Output power: 1W ~ 5W optional .
6. Two-way high voltage output circuits have self-recovery overload
short-circuit protection.
7.Working under natural air cooling conditions, needn't any cooling
device, conversion efficiency: 60% ~ 80% .
8.Industrial temperature range: -40 ~ + 85 ºC .
Product description:
SunYuan the newly developed GRE series of low cost, small size, wide voltage input isolation and regulated dual loop output high voltage module power is an high voltage DC-DC converter in the leading position of the field. This item can operate safely in a wide range of unstable power supply voltage input environment, and can generate isolated and regulated DC high voltage dual loop output through the internal adjustment circuit of the module. GRE series new products adopt SIP 12Pin (single row 12 feet) small size module design, low cost integrated technical solutions make the product have higher DC/DC conversion efficiency and self-recovery overload short circuit protection voltage regulator output function. The wide creepage distance of product's internal and new isolation technology design solution make this high voltage module power supply with 6KVDC isolation between the input and output. And 6KVDC isolation between output loop 1 and loop 2,this technology can effectively isolate the influence of the common mode interference signal from the primary device on the control system,also can effectively isolate the ground loop circulation crosstalk between the primary and secondary ends of the power supply, it can effectively protect the safety threats of equipment and operators by the high voltage potential difference between different ground terminal in power equipment and medical instruments. Products are widely used in power equipment, medical instruments, laser power supplies, ultrasonic instruments, communication facilities, petrochemical industry and mine explosion-proof equipment etc.

SunYuan the newest product GRE series dc dc converter with low cost, small volume, wide voltage input isolation high voltage dual loop output which is widely used in the following instruments and equipments: nuclear testing instruments, electronic anesthesia machines, medical blood analysis, medical X-ray, medical CT, medical Imaging PET and MRI bone density testing, PM2.5 environmental monitoring, 3D printing, automatic test equipment, capacitor charge and discharge, chromatograph, mass spectrometer, carbon dioxide laser, cathode ray tube, photomultiplier tube, insulation breakdown test, electron beam exposure , Capillary gel electrophoresis, protein extraction, DNA sequencing, electrostatic chuck, display driver, flight simulation experiment, micro-channel plate, electrostatic coating, electrostatic flocking, electrostatic precipitator, oil fume and air purification, electrostatic spray (spraying, painting ), Image intensifier, industrial color printing, luggage inspection, food inspection, PCB inspection, nondestructive inspection, thickness gauge, focused ion beam microscope for photomask repair, ion implantation, magnetron, klystron, neutron generator , Spectrometer, agricultural demisting and dew production increase ...At present, Sunyuan Technology Co., Ltd. is efforts to continuously improve the isolated high-voltage power supply product line to meet the growing demands of power, medical, scientific research and other industries.
Model number and definition:

GRExxxxS Series Model Number Example: (The bellow data is the detection value of the product after 8 hours of continuous full load aging)
Model Number |
Input volt Vin(VDC) |
Output Volt/Current |
No-load power consumption(mW) |
Full load efficiency(%) |
Nominal value Vin(VDC) |
Range Vin(VDC) |
Output current Full load (mA) |
Output Volt Vout(VDC ) |
GRE05050050S-1W |
5 |
4.5~9 |
10/10 |
50/50 |
350 |
61 |
GRE05100100S-1W |
5/5 |
100/100 |
62 |
GRE05150150S-1W |
3.4/3.4 |
150/150 |
60 |
GRE05200200S-1W |
2.5/2.5 |
200/200 |
65 |
GRE05250250S-1W |
2/2 |
250/250 |
63 |
GRE05300300S-1W |
1.67/1.67 |
300/300 |
65 |
GRE05400400S-1W |
1.25/1.25 |
400/400 |
64 |
GRE05050050S-2W |
5V |
4.5~9 |
20/20 |
50/50 |
350 |
60 |
GRE05100100S-2W |
10/10 |
100/100 |
61 |
GRE05150150S-2W |
6.7/6.7 |
150/150 |
63 |
GRE05200200S-2W |
5/5 |
200/200 |
62 |
GRE05250250S-2W |
4/4 |
250/250 |
64 |
GRE05300300S-2W |
3.4/3.4 |
300/300 |
62 |
GRE05400400S-2W |
2.5/2.5 |
400/400 |
64 |
GRE12050050S-3W |
12 |
9~18 |
30/30 |
50/50 |
350 |
73 |
GRE12100100S-3W |
15/15 |
100/100 |
76 |
GRE12150150S-3W |
10/10 |
150/150 |
77 |
GRE12200200S-3W |
7.5/7.5 |
200/200 |
75 |
GRE12250250S-3W |
6/6 |
250/250 |
79 |
GRE12300300S-3W |
5/5 |
300/300 |
80 |
GRE12400400S-3W |
3.75/3.75 |
400/400 |
75 |
GRE12050050S-4W |
12 |
9~18 |
40/40 |
50/50 |
350 |
72 |
GRE12100100S-4W |
20/20 |
100/100 |
73 |
GRE12150150S-4W |
13.4/13.4 |
150/150 |
75 |
GRE12200200S-4W |
10/10 |
200/200 |
77 |
GRE12250250S-4W |
8/8 |
250/250 |
76 |
GRE12300300S-4W |
6.7/6.7 |
300/300 |
80 |
GRE12400400S-4W |
5/5 |
400/400 |
78 |
GRE24050050S-5W |
24 |
18~28 |
50/50 |
50/50 |
350 |
72 |
GRE24100100S-5W |
25/25 |
100/100 |
73 |
GRE24150150S-5W |
16.7/16.7 |
150/150 |
75 |
GRE24200200S-5W |
12.5/12.5 |
200/200 |
77 |
GRE24250250S-5W |
10/10 |
250/250 |
76 |
GRE24300300S-5W |
8.4/8.4 |
300/300 |
78 |
GRE12400400S-5W |
6.25/6.25 |
400/400 |
75 |
Remarks: If you need other non-standard output voltage parameters, please contact with Shunyuan Technology Co., Ltd.
Product technical parameters and characteristics:
Project |
Working Condition |
Min |
Typical value |
Max |
Unit |
Output voltage accuracy |
1%-100% load range |
|
±2 |
|
% |
Load Adjustment rate |
Nominal voltage input, load from 10% to 100% |
|
±1 |
|
% |
Linear adjustment rate |
Input voltage range, full load |
|
±1 |
|
% |
Ripple & Noise |
20MHz bandwidth, parallel line test method |
|
±1 |
|
% |
Switch frequency |
Nominal voltage input, full load |
|
200 |
400 |
KHz |
Temperature Coefficient |
Nominal voltage input, full load |
|
0.02 |
|
%/ºC |
stability |
After half an hour of booting, the hourly rate of change |
|
0.001 |
|
%/Hr |
Output short circuit protection |
Output short circuit |
Sustainable,Self-recovery |
Isolation withstand voltage |
Leakage current 1mA, time 60s |
|
6000 |
|
VDC |
Pin soldering temperature |
Welding point ≥1mm from the shell, 10s |
|
+300 |
|
ºC |
Insulation resistance |
Input/Output,500VDC,25ºC,70%RH |
|
1000 |
|
MΩ |
Working temperature |
|
-40 |
|
+85 |
ºC |
storage temperature |
|
-55 |
|
+105 |
ºC |
Storage humidity |
No condensation |
|
|
95 |
%RH |
cooling method |
|
Natural air cooling |
Hot swap |
|
Don't support |
MTBF |
MIL-HDBK-217F@25ºC |
1000 |
|
|
KHours |
Shell material |
|
Plastic shell-PVC flame retardant material |
Packaging Size |
Length * width * height |
33.0 x 10.5 x 15.5 |
mm |
Weight |
|
|
10 |
|
g |
Safety precautions and conventional methods of product high voltage isolation test:
1,As show above picture 1: Set the rated high voltage value according to the product isolation voltage specifications. Please pay attention to personal safety when testing and beware of electric shock!
Test condition: room temperature TA = 25 ºC, humidity <75%
2,The operator of the withstand voltage test must wear rubber insulation (insulation voltage> 10KV) gloves, and place insulation pads on the workbench and seat floor to prevent high voltage electric shock.
3,The pressure tester instrument must be reliably grounded and cannot be detected in a high temperature, humid and dusty environment.
4,When the withstand voltage tester is connected to the test object, it cannot be operated with power on, and the output voltage value of the high voltage tester must be zero.
5,When the instrument is in the startup state or the high voltage is not released, it must not touch the measured object, test line or high voltage test line and test fixture.
6,The product test method like above picture 1: all pins of the input and output terminals are connected in parallel, and the test is performed for 1 minute according to the isolation voltage value given by the product.
7,According to the test standard for withstand voltage, the withstand voltage value is gradually adjusted upward from 0. When the withstand voltage value is adjusted to the set maximum withstand voltage and maintained at the highest withstand value for one minute.
8,The pressure test itself is a destructive test. The fewer times the product should be done, the better. If the customer needs multiple tests, the general requirements are: the first measurement is based on the voltage value of the specification, and the voltage value should be reduced accordingly for each subsequent test, otherwise the product performance will be reduced or directly damaged.