Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter

Product Details
Customization: Available
Type: Normal Pressure Transmitter
Accuracy Grade: 0.2G
Still deciding? Get samples of US$ 117/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
27
Year of Establishment
2002-09-10
  • Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
  • Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
  • Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
  • Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
  • Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
  • Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
Find Similar Products

Basic Info.

Model NO.
ISOH 4-20mA
Certification
CE. RoHS ,FCC
Customized
Customized
Continuous Isolation Voltage
10000vrms
The Max Voltage of Input
32VDC
Working Temperature
+85c
Storage Temperature
+150c
Output Short Circuit Time
Sustainable
Linearity Error Grade
0.1 0.2grade
Auxiliary Power
No
Impulse Withstand Voltage-
10kvac
Payment Way
Paypal , T/T
Lead Time
3-4days
Shipping Way
DHL , FedEx
Item Packaging
SIP16 Pin
Withstand Voltage
10kv(50Hz / 60s)
Leakage Current
Less Than 1mA
Model Number
Isoh 4-20mA
Transport Package
Tube and Color Box
Specification
10g/pc
Trademark
SunYuan SZ
Origin
Shenzhen
HS Code
8543709200
Production Capacity
50000PCS Per Month

Product Description

               ISOH 4-20mA 10KVAC High Isolation 4-20mA Curent Input And Ouput Analog Signal Transmitter

                    4-20mA(0-20mA) Two-wire and passive current loop high isolation IC: ISOH 4-20mA series

Product features:
1.Unique high-efficiency signal loop technology of power supply from coupling,without an external source of power.
2.10KVAC high voltage isolation technology for signal input/output loops at both of ends
3.4-20mA(0.1,0.2grade)signal high precision undistorted transmission technology
4.Extremely high linearity in the 4-20mA full range, nonlinearity error <0.2%
5.4-20mA loop power supply ultra-wide range voltage input (8.5~32VDC)
6.The loop signal takes a lower voltage drop (3.5VDC / Type @20mA)
7.Industrial grade enviroment temperature range: -40 ~ +85 °C
8.Small size standard single column SIP 16Pin accord with UL94V-0 flame retardant package

Typical application:
1.4-20ma current loop signal high voltage isolation safety barrier 
2.Power instrumentation, medical equipment monitoring isolation safety barrier
3.Rail transit DC high voltage monitoring isolation safety barrier
4.Signal acquisition isolation and anti-interference between PLC and DCS input channels
5.Ground loop interference suppression for power transmission and distribution control system
6.Multi-channel instrumentation and sensor signal reliable transmission and reception monitoring
7.Analog signal data acquisition isolation and long line undistorted transmission
8.High isolation between the electric load and power management instrument bus interface
Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
SunYuan ISOH 4-20mA is our the newest developed two-wire passive 4-20mA current loop isolation module in industry circles with the highest isolation voltage (10KVAC) and small size (16-pin single-in-line SIP16 Pin) &low-cost. This new product is a passive analog signal isolation hybrid integrated circuit of front-end 4-20mA current signal input and back-end 4-20mA output, IC internal including the current signal modulation and demodulation circuit, signal coupling isolation conversion circuit, etc. . This new product adopts the unique Sunyuan technology magnetic-electric coupling isolation and high-efficiency loop power take-off invention technology, which effectively solves the problem of dependence of the signal isolation circuit on the power supply during operation, and can realize high-precision, high-linearity 10KV anti-EMS high-isolation transmission of 4-20mA (0-20mA) signal between the industrial field sensors & instrumentation, PLC &DCS. The 16pin SIP small size (46X22X12mm) standard PCB mounting design can be embedded in the instrument panel, sensor, PLC and other operation control boards, which simplifies the user system design choice and reduces the volume and wiring cost.

Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
ISOH 4-20mA adopts Sunyuan's unique electromagnetic isolation coupling technology, which does not require independent power supply and has a small input equivalent resistance inside, which makes the input voltage of the IC reach an ultra-wide range (8.5~32VDC). The technical products can be directly connected in the two-wire 4-20mA or 0-20mA working circuit of industrial field PLC, instrumentation and sensor, physical transmitter and other devices, and can achieve 4-20mA signal anti-interference isolation, long-distance distortion-free transmission without external auxiliary power supply.. The integrated process and new technology isolation measures inside the product enable the input and output ports of the device to achieve a high isolation insulation voltage of 10KVAC and can meet the harsh environment requirements such as wide temperature, humidity and vibration in the industrial field. The products are IC module package and DIN35 Rail-mounted packaging, It is widely used in track voltage monitoring, generator or motor safe operation monitoring, power transmission and distribution remote monitoring, instrumentation and sensor signal transmission and reception, medical equipment safety barrier, industrial intelligent control, nuclear power equipment and other fields.

The Real Picture :
Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal TransmitterIsoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal TransmitterIsoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
The Maximum rating of product (long-term operation in the maximum rated environment affects the service life of the product and irreparable damage may occur if beyond the maximum value.)
Continuous Isolation Voltage                                                           10000Vrms
Vin (The Max voltage of input)                                                       32VDC
Working Temperature                                                                  +85 ºC
Storage Temperature                                                                   +150ºC
Lead Temperature                                                                     +300ºC
Output short circuit time                                                               Sustainable
General parameters
Accuracy, linearity error grade ---------- 0.1,0.2grade Load regulation rate --------- <0.05% meas.val./100Ω 
Auxiliary power ---------- no Isolation ---------- Signal input / signal output,two isolated
Working Temperature ---------- -40 ~ +85ºC   Packaging ----------SIP16 Pin
Working humidity--------10 ~ 90%( No condensation ) Withstand voltage --- 10KV(50HZ / 60S), Leakage current <1mA
Storage Temperature ---------- -45~ +105ºC      impulse withstand voltage---------- 10KVAC, 1.2/50us( peak value )
Storage  humidity-------10 ~ 95% ( No condensation ) temperature drifting ---0.0050%F.S./ºC (-40ºC~ +85ºC range)

Technical parameters
Parameter Condition Min Typical value Max Unit
Isolation voltage AC, 50Hz
Insulation resistance
Leakage current
60S
500VDC
240Vrms,50Hz
  10000
100
0.5
  Vrms

uA
Temperature drifting
Nonlinearity
-40~+85ºC
Within full scale
  ±50
±0.1
±100
±0.2
PPm/ºC
%FSK
Input signal voltage range   8.5   32 V
Output linear range
Output current Io
Output pressure drop Voh


Io=20mA
0
0.1
4

3.5
20
40
mA
mA
V
Output load capacity Io=20mA   250   Ω
Frequency response (small signal bandwidth) Io=20mA   100   Hz
Dimensions and pin definitions:
Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
 Pin function description(SIP16 Pin)
signal
Input
Positive end
signal
Input
Negative end
empty

foot
signal
Output
Negative end
signal
Output
Negative end
signal
Output
Positive end
signal
Output
Positive end
Iin+ Iin- NC Iout- Iout- Iout+ Iout+
1 2~3 4~12 13 14 15 16

Typical application:
Isoh 4-20mA 10kvac High Isolation 4-20mA Curent Input and Ouput Analog Signal Transmitter
High voltage isolation safety test method and precautions:
1. Reffering to the wiring shown in the above figure, setting the rated high voltage value of the high voltage tester according to the product isolation voltage parameter specification. Please pay attention to personal safety when testing, beware of electric shock!
Test environment: room temperature TA = 25 ° C, air humidity < 75%
2. The high voltage test operator must wear rubber-insulated gloves with rubber insulation pads on the ground to avoid high voltage electric shock.
3. The instrument housing of the high voltage tester must be grounded reliably and should not be detected in a high temperature, humid and dusty environment.
4. When connecting the measured object, the high voltage tester must ensure that the high voltage output value is "0" and the detection function key is "reset" to prevent contact with other objects.
5. When the instrument is in the high voltage test state and before the end of high voltage discharge, it is strictly forbidden to contact the measured object, test line or high voltage output.
6. Product isolation voltage test method as shown in the above figure, short the input terminal and output terminal pin respectively and load the rated voltage value for 1 minute.
7. According to the rated isolation voltage value of the product, use the output voltage of the manual gear to adjust tester from 0 to the rated value and keep it for a minute.
8. The insulation voltage test itself is a destructive test of the insulator. For the same product, the high voltage test should be minimized. If there are multiple tests between different customers, the general requirements are as follows: the batch product is tested according to the rated voltage value of the specification for the first time, and the test voltage value should be reduced by 0.7 times of the rated value each time. The number of high voltage tests, otherwise the product will be irreparable damage during multiple high-voltage tests..


For more information, please feel free to contact us:
Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download: 
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA 
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series 
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F 
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA 

Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download: 
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC  
2,
 ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC 
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC 
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter

8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter 
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter 
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring 
13,ISO F-P-O  Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier 
16.Large current output type high precision signal transmitter













 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier