• Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
  • Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
  • Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
  • Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
  • Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
  • Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning

Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning

Type: 10kv High Isolation Transmitter
Structure Type: 10kv High Isolation Transmitter
Measuring Medium: Current Signal
Accuracy Grade: 0.1G
Certification: CE, RoHS
Customized: Customized
Samples:
US$ 117/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ISOH 4-20mA-O
Accuracy, Linearity Error Grade
0.1, 0.2
Auxiliary Power
No
Input
4-20mA
Output
0-2.5V, 0-5V, 0-3.3V, 1-5V Customized
Isolation Voltage
10kv
Lead Time
3-4working Days
Warranty
2 Years
Packaging Ways
SIP , DIN35 Rail-Mounted Packaging
Shipping Way
DHL , FedEx etc
Payment Way
T/T, Paypal
Keywords1
4 to 20 Ma Converter
Keywords2
4-20mA Converter
Keywords3
Analog Signal Converter
Keywords4
4-20mA Converter IC
Keywords5
4-20mA Converter Chip
Transport Package
Plastic Tube + Carton Box
Specification
SIP 16Pin, DIN3, DIN35
Trademark
Sunyuan or OEM
Origin
Guangdong, China
HS Code
8543709200
Production Capacity
50000PCS Per Month

Product Description

ISOH 4-20mA-O high isolation 4-20mA to 0-5V isolation signal conditioning
 
Introduction:
SunYuan ISOH 4-20mA-O is the highest isolation voltage 10KVAC in the industry fied, small size (16pin single-line SIP16 Pin) low cost, two-wire passive 4-20mA to voltage signal isolation converter module. The voltage signal value can be converted by sampling acquisition isolation in a two-wire passive 4-20mA current loop without a separate power supply. The IC adopts two-wire input loop power supply mode, unique high-efficiency signal loop power-taking technology and no external working power supply, which can greatly simplify the user's system design and reduce the user wiring cost. The internet of IC including a current signal modulation and demodulation circuit, a signal coupling isolation conversion circuit, a power supply inverter circuit, a subtraction circuit, a buffer processing output circuit, etc., and a small input equivalent resistance enables the IC to be used from instruments, PLCs, and sensors. The current signal is collected in the signal loop (the voltage drop is ≤10V when the input 20mA signal is reached), and the collected current signal is isolated and converted into a voltage signal. It is convenient to realize the AD acquisition and conversion of the industrial field MCU microcontroller, DCS, FCS and other control systems. It meets the needs of the user's site without the need for an external auxiliary power supply or IV conversion transmitter to achieve long-distance, distortion-free transmission of signals.
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning

Features:
1. Unique high-efficiency signal loop power-taking technology, no external working power supply
2. Two-wire 4-20mA standard analog input, isolation amplifier converted to Analog voltage signal such as 0 2.5V/0-3.3V/0-5V/1-5V. 
3. Very low input impedance, voltage drop ≤10V when meet inputting 20mA signal.
4. Accuracy level: 0.1, 0.2, 0.5
5. Extremely high linearity over the full range, nonlinearity error < 0.2%
6. Between signal input and output: 10000VAC high isolation
7. Industrial temperature range: -40 ~ +85 °C
8. Small size single row SIP 16Pin, meets the UL94V-0 flame retardant package

Typical Application:
1. Two-wire passive 4-20mA loop voltage sampling acquisition isolation implementation.
2. Industrial field analog signal AD sampling conversion and remote transmission
3. Sensor and transmitter 4-20mA signal isolation and IV conversion 
4. Signal acquisition isolation and anti-interference between PLC and DCS input channels  
5. Multi-channel analog acquisition ground loop isolation and interference suppression
6. Reliable transmission and reception monitoring between instrumentation signals and sensors
7. Analog signal data acquisition isolation and long-line distortion-free transmission  
8. Power instrumentation, medical equipment monitoring isolation barrier
9. DC, high voltage monitoring and isolation safety barrier for electric power and rail transit

Model Selection:
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
The Real pictures:

SIP Packaging way:
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning

DIN35 Rail-mounted packaging :
 
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning

ISOH 4-20mA-O is often used for the isolation conversion of two-wire passive 4-20mA current to voltage signals. It has low power consumption and low heat generation (basically no temperature rise)high reliability. The internet mainly including the subtraction circuit and the amplifier buffer output circuit. These circuits bring the advantages of simplicity and reliability and also bring the limitations of use. Both the product and the 4-20 mA signal output from the sensor are isolated and transmitted from the other. From another definition it is the transmission of electric power, so there must be power loss inside. This loss is expressed in the product of the input current value and its own input voltage drop. In this case, the 4-20 mA source must have the ability to drive a 500 Ω load for the product to function properly. At present, from the practical application experience of industrial sites, most of the field instruments and sensors, PLC / DCS, etc. can meet the ability of 4-20mA signal output to drive 500Ω load.

In industrial field applications, some circuits can convert the input current signal into a voltage signal using only one I/V conversion sampling resistor. This circuit is simple but not practical. First of all, when the actual meaning is zero signal, there will be a zero current flowing through the sampling resistor. If the input current is converted to the maximum 5V voltage according to the 4~20mA input current, the zero point happens to be 1V. This 1V is sufficient in the MCU resources. At that time, it can be subtracted by the microcontroller software, but the useful voltage will leave 5-1=4VDC instead of 5VDC. Since the maximum input voltage of the A/D of the MCU is the supply voltage of the MCU, this voltage is usually 5 VDC, so it is very trouble to deal with this simple input conversion circuit. In order to achieve the number of A/D conversions, the cost of the chip will increase. . A simple way to solve the above problem is to configure a subtraction and buffer processing circuit composed of an operational amplifier before the input of the single-chip microcomputer. Increasing this level of circuit can make the processing of the zero point more convenient, without consuming the internal resources of the single-chip microcomputer, especially the single-chip microcomputer. When the A/D interface is used to accept such a zero signal and the input is not zero voltage value, the resources of the A/D conversion bit number can be fully applied to the useful signal.

ISOH 4-20mA-O series enables high-precision, high-linearity 10KV anti-EMC high-isolation transmission and I/V conversion between industrial field sensors and instrumentation, PLC and DCS. Products include IC PCB package and DIN35 Rail-mounted packaging, It is widely used in track voltage monitoring, generator or motor safe operation monitoring, power transmission and distribution remote monitoring, instrumentation and sensor signal transceiver, medical equipment safety barrier, industrial automation control, nuclear power equipment etc other fields.
Rated Maximum Values:
(Operating the products in the rated maximum value environment for long-term will affects the service life of the product. If the maximum value is exceeded, irreparable damage may be occurred.)
Continuous Isolation Voltage                                                                                      10000Vrms
Junction Temperature ( Maximum working temperature range )                                  - 40 ~ +85 ºC
Lead Temperature     ( Pin highest soldering temperature / duration <10S )               +300ºC/<10S
Output voltage signal minimum load                                                                            5KΩ

General Parameters:
Accuracy, linearity error level ---------- 0.1,0.2grade Backlash  ---------- < 0.5%
Auxilary power supply----------  NO Isolatoin ---------- Signal input/output,two isolation
Working temperature----------  -40 ~ +85ºC   Insulation resistance  ---------- ≥20MΩ
Working humidity ---------10 ~ 60% (No condensation) Pressure resistance-10KV(50HZ / S),Leakage current 1mA
Storage temperature----------  -45~ +85ºC     Withstand voltage--------- 10KVAC, 1.2/50us  (peak)
Storage humidity----------10 ~ 95% (No condensation)  

Technical Parameters:
Parameters Condition Min value Typic value Max value Unit
Isolation voltage   AC,50Hz
Insulation resistance
Leakage current
60S

240Vrms,50Hz
  10000
10¹²‖1
0.5
  VAC
Ω‖Pf
uA
Temperature drift
Nonlinearity
    ±50
±0.2
±100
±0.5
PPm/ºC
%FSK
load capacity Vout=5VDC 5 10  
Input signal voltage range   9 24 36 VDC
input resistance Iin=20mA,Out=5V 450 500   Ω
Output signal voltage range RL:5KΩ 0   5 VDC
Output linear range
Output current  Io

 
0
0.5
  5
1.2
V
mA
Output signal ripple No filtering   10 20 mVRMS
Frequency response (small signal bandwidth) Vo=5V   100 200 Hz
Response time     10 20 mS
Working temperature   -40   85 ºC
Storage temperature   -55   105 ºC

Pin Definition and Block Diagram:
Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning


Dimension and Typical application:

Isoh 4-20mA-O High Isolation 4-20mA to 0-5V Isolation Signal Conditioning
For more information, please feel free to contact us:
Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download: 
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA 
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series 
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F 
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA 

Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download: 
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC  
2,
 ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC 
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC 
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter

8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter 
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter 
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring 
13,ISO F-P-O  Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier 
16.Large current output type high precision signal transmitter

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now