Customization: | Available |
---|---|
Model: | ISO 4-20mA |
Input: | 4-20mA |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Conditions | Min. | Typical Value | Max. | Unit |
Isolation Volt. AC, 60Hz Insulation Impedance Leak current |
10S 240Vrms, 60Hz |
1000 | 2500 10¹²II1 0.5 |
6000 | Vrms ΩIIPf uA |
Temp. Drift Non-linearity |
-45~+85ºC In range of full span | ±50 ±0.1 |
±100 ±0.2 |
PPm/ºC %FSK |
|
Input Signal Volt. Range | 7.5 | 12 | 32 | V | |
Output Linearity Range Output Current Io Output Voltage Drop Voh |
Io=20mA |
0 0.1 |
4 2 |
20 40 |
mA mA V |
Output Signal Ripple | 5 | mV | |||
Frequency Response (small signal bandwidth) |
Io=20mA | 2 | KHz |
Accuracy, linearity error grade ---------- 0.1, 0.2 | Hysteresis error ---------- < 0.5% |
Auxiliary power---------- No | Isolation ---------- signal input and output |
Operating Temp. ---------- -20 ~ +70ºC | Insulation Resistance ---------- ≥20MΩ |
Operating Humidity ---------10~90% (no condensation) | Withstand Voltage ---------- 3KV(60HZ/S), leak current 1mA |
Storage Temp.---------- -20 ~ +70ºC | Impact Resistance Volt. ---------- 3KV, 1.2/50us (peak value) |
Storage Humidity -------10 ~ 95% (no condensation) |