8-Channel Analog to Digital Signal Converter with Modbus RTU

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Manufacturer/Factory & Trading Company
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
27
Year of Establishment
2002-09-10
  • 8-Channel Analog to Digital Signal Converter with Modbus RTU
  • 8-Channel Analog to Digital Signal Converter with Modbus RTU
  • 8-Channel Analog to Digital Signal Converter with Modbus RTU
  • 8-Channel Analog to Digital Signal Converter with Modbus RTU
  • 8-Channel Analog to Digital Signal Converter with Modbus RTU
  • 8-Channel Analog to Digital Signal Converter with Modbus RTU
Find Similar Products

Basic Info.

Model NO.
ISO AD16 Series
Input
4-20mA/0-20mA/0-10V,etc
Output
RS232/RS485
Isolation Voltage
3000kvdc
Communication Port
RS232 or RS485
Channels
16-CH
Appearance & Dimension
158*87.5*59mm
Operation Temperature
- 45 ~ +80 Centigrade
Endure Impact Voltage
3kvac, 1.2/50us(Peak Value)
Export Market
Global
Transport Package
DIN-Rail
Specification
ISO9001: 2008, CE, ROHS
Trademark
YUAN
Origin
Shenzhen
Production Capacity
50000PCS/Year

Product Description

8-Channel Analog to Digital Signal Converter with Modbus RTU

ISOAD 16 A-D Converter General Parameters:

(typical @ +25ºC,Vs @ 24VDC)

Input:  Voltage / Current

Accuracy:  @ +25ºC  as table 1

Nonlinearity :  @ +25ºC  as table 1

Input imbalance:  ±0.1 uA/ºC

Temperature Drift:  ±15 ppm/ºC (±30 ppm/ºC, max)

Input load:  50Ω (4-20mA/0-20mA/0-±20mA current input) 

            100Ω (0-10mA/0-±10mA current input)

            1KΩ (0-1mA/0-±1mA current input)

            >1MΩ (voltage input)        

Band width:  -3 dB 10 Hz

Switching rate:  2.5-30 KHz Sps

Common mode restraint (CMR): 120 dB(1kΩ Source Imbalance @ 50/60 Hz)

Normal mode restraint (NMR): 60 dB (1kΩ Source Imbalance @ 50/60 Hz)

Input terminal protection: over-voltage/over current protection

Communications Protocol:  RS-485 or RS-232 ASCII character protocol and standard MODBUS RTU communication protocol

Baud rate: 300,600,1200,2400,4800,9600,19200,38400bps,57600,115200bps , selectable

Address: 0~255 , selectable

Response Time:100 ms max

Operation Power Supply: +24VDC+-10%, internal anti-reverse & over-voltage protection               

watt consumption:  <8W

Operation Temperature:  - 45 ~ +80ºC         

Operation Humidity: 10 ~ 90% (non-condensing)

Storage Temperature: - 45 ~ +80ºC             

Storage Humidity: 10 ~ 95% (non-condensing)                                    

Isolation withstand voltage: 3KVDC between input and output, 1 minute, stray current 1mA

                         Output and power are common-ground.

Endure Impact Voltage: 3KVAC, 1.2/50us(peak value)

Appearance & dimension:  158*87.5*59mm 

8-Channel Analog to Digital Signal Converter with Modbus RTU
8-Channel Analog to Digital Signal Converter with Modbus RTU
8-Channel Analog to Digital Signal Converter with Modbus RTU
8-Channel Analog to Digital Signal Converter with Modbus RTU



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier