ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter

Product Details
Customization: Available
Item No.: ISO R4-P2-O1
Input Signal: 0-500ohm
Manufacturer/Factory & Trading Company
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
27
Year of Establishment
2002-09-10
  • ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
  • ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
  • ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
  • ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
  • ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
  • ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
Find Similar Products

Basic Info.

Model NO.
ISO R4-P2-O1
Output Signal
4-20mA
Auxiliary Power
12V
Industrial Grade Temperature Range
- 40 ~ + 85 Degree
Accuracy
(Non-Isolation)0.1, (Isolation)0.2
IC Type
Electrical Ruler Embedded\Water Proof Case and Di
Work Temperature
-25 ~ +70 Degree
Storage Temperature
45 ~ +80 Degree
Warranty Time
Two Years
Transport Package
Paper Box
Specification
29.5X20X5.5cm
Trademark
Sunyuan or OEM
Origin
Guangdong, China
HS Code
9026900000
Production Capacity
50000PCS Per Month

Product Description


ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter

Characteristics:
Resistance, potentiomerter,electrical ruler, position sensor signal input
Accuracy Grade: (Non-isolation)0.1, (Isolation)0.2
Internally installed linear processing and long-line compensation circuit(non-linearity<0.05%)
Auxiliary power, signal input and output three port isolation:3000V DC
Auxiliary power supply:5V/12V/15V or 24V DC Single supply.
Input potentiometer signal:0-50Ω/0-500Ω/0-2KΩ/0-10KΩ Output standard voltage signal:0-2.5V/0-5V/0-10V/1-5V/ Ouput Standard current signal:0-10mA/0-20mA/4-20mA.
IC type,electrical ruler embedded,Water proof case and DIN35 Din-rail install method.
Industrial grade temperature range:- 40 ~ + 85 ºC.

Applications:
Electrical ruler ,angular transducer signal isolation, acquisition and conversion.
Displacement ,potentiometer signal acquisition/isolation and control.
earth wire interference suppression on industrial site.
Resistance signal convert to standard analog signal.
Distance measurement and Alarm.
Analog signal long-term distortionless transmission.
CNC,Rail transit equipment displacement control and isolation safety Barrier.

Description:
    Sunyuan ISO V-4-20mA and ISO R-P-O series isolation amplifier is a kind of integrated circuit that can convert and isolate position resistance signal into standard signal that linear to resistance according to change in size. It integrates a set that multi-channel high isolated DC-DC converter, some high-powered signal isolators, and resistance linearization,long-term compensation, interference suppression circuits in single chip. Especially apply to convert/isolate resistance signal to standard signal, transmission of position signal, Electrical ruler, angular transducer signal isolation, acquisition and conversion.
    The inner of the chip integrates high-efficiency DC-DC converter that produces two sets  of isolated power separately supply for inner input port amplifier circuit, modulator circuit and output port demodulator circuit, conversion circuit, filter circuit. SMD technology and new technique quarantine measures make it's isolation voltage among auxiliary power supply, signal input, signal output up to 2500V AC, and meet industrial site temperature/humidity/vibration mal-environment requirements.
    ISO V-4-20mA and ISO R-P-O series position signal isolation amplifier is easy to use, only need a few external component, then can realize position resistance signal transducer and isolation. And can realize industrial site one in two out and even one in four out.SY series input output non-isolated type product, has high precision and linearity (>0.05F.S), it usually applied in bull-in electrical ruler, angular displacement signal transducer etc, precision measuring instrument. Small size, easy stall. It can be installed inner of the sensor, directly convert the position, angular signal to standard 4-20mA signal. Zero and Span can be adjusted through external potentiometer.

 

Category 
Isolation Amplifier >> Displacement Sensor Signal Isolation Amplifier
   
Inputput   0-50Ω/0-500Ω/0-2KΩ/0-10KΩ,etc output  0-2.5V/0-5V/0-10V/1-5V/0-10mA/0-20mA/4-20mA,etc
Isolation methoad photoelectricity isolation Output 3000VDC
Package:  IC type and DIN35    
Remark   Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Transmitter
ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
ISO R-P-O Potentiometer/Resistance/Electrical Ruler Signal to 4-20mA/0-5V/0-10V Isolated Signal Transmitter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier