• Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
  • Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
  • Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
  • Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
  • Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
  • Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device

Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device

After-sales Service: 2 Years
Warranty: 2 Years
Input: Thermocouple Signal
Output: RS232/RS485
Communication Port: RS232 or RS485
Channels: 8-Channel
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SY AD08T
Package
DIN-Rail
Weight
About 120g
Dimension
101 Mm X 23 Mm X 116.5 Mm
Operation Temperature
45 ~ +85 Centigrade
Endure Impact Voltage
3kvac, 1.2/50us(Peak Value)
Export Market
Global
Transport Package
DIN Rail Mounting Type
Specification
CE, ISO9001: 2008
Trademark
SUNYUANSZ
Origin
Shenzhen
HS Code
8543709200
Production Capacity
50000PCS/Month

Product Description

8 Channels Thermocouple Signal to RS232/RS485 A-D Converter

Features:
-8 Channels thermocouple signal data acquisition, isolates and converts into RS485/RS232 output.
-Measurement accuracy is better than 0.5%.
-Programmable calibration of module precision is available.
-One-channel DS18B20 Temperature sensor inside is used to compensate the thermocouple cold junction.
-Low cost, small size module, easy to use in installation
-J/ K/ T/ E/ R/ S/ B types thermocouple signal input
-User can programme and set input range
-Wide range input power: 8---50V DC
-Isolation between signal input and output: 3000VDC
-Support MODBUS RTU communication protocol

Applications:
-Measure, monitor and control temperature signals
-Intelligent building control, Security and engineering application
-RS-232/485-bus industrial automation control system
-Industrial field signal isolation and long-term transmission
-Thermocouple signal isolated conversion and long-term transmission
-Analogue signal A/D conversion, adjustment and long-term transmission
-Small signal measurement
-Industrial field data acquisition and record
-Application in medical, industrial products development

Description:

SY AD 08TSeries products achieve the signal data acquisition between sensor and host which are used to measure analog signal or control remote equipments. And through the configuration of software, they can be used in various types of sensors including: Analog signal input, analog signal output and digital signal input and output. SY AD 08T Series products can also be used in industrial automation RS232/485-bus system, thermocouple signal measurement, monitoring and control, small signal measurement and industrial-site signal isolation and long-term transmission.
The products include power supply isolation, signal isolation between input and output, A/D conversion and RS485 series communication circuit module. Each port can connect maximum 256 pieces of SYAD08T series modules, and adopts ASCII character communication protocol or MODBUS RTU communication protocol in communication whose instructions set compatible with ADAM module, the baud rate set by user. And the product can hang in the same RS-485 bus with control model from other manufactures to facilitate host programming.

Model Sellection:

SYAD08T-_
Thermocouple Types:
J: J type
R: R type
K: K type
S: S type
T: T type
B: B type
E: E type

Input Range Description Accuracy
(Typical)
Accuracy (Maximum) Noise
(Peak-to-Peak)
Type J thermocouple,0ºC-760ºC ±0.2ºC ±0.4ºC ±0.12ºC
Type K thermocouple,0ºC-1000ºC ±0.25ºC ±0.5ºC ±0.2ºC
Type T thermocouple,-100ºC-00ºC ±0.2ºC ±0.35ºC ±0.15ºC
Type E thermocouple,0ºC-000ºC ±0.18ºC ±0.4ºC ±0.1ºC
Type R thermocouple,500ºC-750ºC ±0.3ºC ±0.8ºC ±0.22ºC
Type S thermocouple,500ºC-750ºC ±0.3ºC ±0.75ºC ±0.2ºC
Type B thermocouple,500ºC-800ºC ±0.4ºC ±0.9ºC ±0.3ºC

 

Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device
Multi-Range High Precision J/K/T/E/R/S/B Types Thermocouple Signal Isolator Data Acquisition Module Device

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now