• DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
  • DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
  • DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
  • DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
  • DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
  • DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator

DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator

Task: Following
Structure: Open-Loop
Mathematical Model: Linear
Signal: Continuous
Function: Monitoring
Certification: CCC, ISO: 9001, CE
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DIN1X1 ISOEM-A7- P2- O7
Condition
New
Customized
Customized
Material
Plastic
Item No
DIN1X1 Isoem-A7- P2- O7
Input Signal
0- Positve and Negtive 20mA
Auxiliary Power
12V
Output Signal
0-Positve and Negtive 5V
Accuracy
0.2% /0.5%
Operating Temperature
-25 ~ +70degree
Operating Humidity
10 ~ 90% (Non-Condensing)
Storage Temperature
-45 ~ +80degree
Storage Humidity
10 ~ 95% (Non-Condensing)
Isolation Voltage
3000V
Transport Package
PP Bag and Gift Box
Specification
10g
Trademark
Sunyuan or OEM
Origin
Guangdong, China
Production Capacity
50000PCS Per Month

Product Description

DIN Rail DC Current/Voltage 4-20mA/0-5V/0-10V Isolation Trasnmitter DIN1x1 ISOEM U(A)-P-O

Description
DIN Rail DC Current/Voltage 4-20mA/0-5V/0-10V Isolation Trasnmitter(No Gain/Zero Adj.)
Characteristic:
·Efficiency grade: 0.1/0.2/0.5
·International standard signal input: 0-5V/0-10V/1-5V/0-±5V/0-±10V , 0-10mA/0-20mA/4-20mA
·Output internal signal with high load capability: 5V/0-10V/1-5V/0-±5V/0-±10V,0-10mA/0-20mA/4-20mA and so on
·Extremely high linearity in whole process(Nonlinearity<0.1%)
·Three-port Isolation:Input/output/power,need not ZA and Gain adjustment.
·Can not use in strong magnetic field Situation
Application Solutions:
The Universal Connection Solutions for Industrial Sensor and Instruments (ISO 4-20mA) Series
The External Protection of Isolation Amplifier Transmitter IC
 
Model Selection:
DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal IsolatorDIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator
DIN Rail Mounted 2 Input and 2 Ouput DC Current Voltage 4-20mA/0-5V/0-10V Signal Isolator


For more information, please feel free to contact us:
Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download: 
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA 
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series 
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F 
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA 

Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download: 
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC  
2,
 ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC 
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC 
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter

8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter 
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter 
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring 
13,ISO F-P-O  Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier 
16.Large current output type high precision signal transmitter




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now