Input: 4-20mA/0-20mA/0-10V,etc
Output: RS232/RS485
Isolation Voltage: 3000kvdc
Communication Port: RS232 or RS485
Channels: 16-CH
Package: DIN-Rail
Samples:
US$ 295/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ISO AD16
Appearance & Dimension
158*87.5*59mm
Certificates
CE RoHS ISO9001:2000/2008
Export Market
Global
Feature
3kv Isolation From Channel to Channel
Transport Package
Standard
Specification
CE ISO9001-2008
Trademark
Sunyuan
Origin
China
Production Capacity
1000/Month

Product Description

0-75mv,0-20ma to RS232 RS485 Data Acquisition Device 

Model selection

ISOAD16 U(A) -

U/A: Vin/Iin Communication interface
U1: 0-5V A1: 0-1mA 485: Output is RS-485 interface
U2: 0-10V A2: 0-10mA 232: Output is RS-232 interface
U3: 0-75mV A3: 0-20mA
U4: 0-2.5V A4: 4-20mA
U5: 0-± 5V A5: 0-± 1mA
U6: 0-± 10V A6: 0-± 10mA
U7: 0-± 100mV A7: 0-± 20mA
U8: Customized A8: Customized
Note: User could choose RS-485 or RS-232 output by the interface wiring jumper at the back of the product.
1: ISOAD16 A4-485 Means 4-20ma signal output, output is RS485 interface
2: ISOAD16 A7-232 Means 0-5V signal output, output is RS232 interface

ISOAD 16 A-D Converter General Parameters:
(typical @ +25º C, Vs @ 24VDC)
Input: Voltage / Current
Accuracy: @ +25º C as table 1
Nonlinearity: @ +25º C as table 1
Input imbalance: ± 0.1 uA/º C
Temperature Drift: ± 15 ppm/ (± 30 ppm/º C, max)
Input load: 50Ω (4-20mA/0-20mA/0-± 20mA current input)
100Ω (0-10mA/0-± 10mA current input)
1KΩ (0-1mA/0-± 1mA current input)
>1MΩ (voltage input)
Band width: -3 dB 10 Hz
Switching rate: 2.5-30 KHz Sps
Common mode restraint (CMR): 120 dB(1kΩ Source Imbalance @ 50/60 Hz)
Normal mode restraint (NMR): 60 dB (1kΩ Source Imbalance @ 50/60 Hz)
Input terminal protection: Over-voltage/over current protection
Communications Protocol: RS-485 or RS-232 ASCII character protocol and standard MODBUS RTU communication protocol
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400bps, 57600, 115200bps, selectable
Address: 0~255, selectable
Response Time: 100 ms max
Operation Power Supply: +24VDC+-10%, internal anti-reverse & over-voltage protection
Watt consumption: <8W
Operation Temperature: - 45 ~ +80º C
Operation Humidity: 10 ~ 90% (non-condensing)
Storage Temperature: - 45 ~ +80º C
Storage Humidity: 10 ~ 95% (non-condensing)
Isolation withstand voltage: 3KVDC between input and output, 1 minute, stray current 1mA
Output and power are common-ground.
Endure Impact Voltage: 3KVAC, 1.2/50us(peak value)
Appearance & dimension: 158*87.5*59mm
item no ISO AD16
0-75mv, 0-20mA to RS232 RS485 Data Acquisition Device
0-75mv, 0-20mA to RS232 RS485 Data Acquisition Device
0-75mv, 0-20mA to RS232 RS485 Data Acquisition Device
0-75mv, 0-20mA to RS232 RS485 Data Acquisition Device
0-75mv, 0-20mA to RS232 RS485 Data Acquisition Device
0-75mv, 0-20mA to RS232 RS485 Data Acquisition Device








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now