• SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
  • SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
  • SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
  • SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
  • SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
  • SIP 12pin Two Wire Passive 4-20mA Signal Conditioning

SIP 12pin Two Wire Passive 4-20mA Signal Conditioning

Task: Adjust
Structure: Combination
Mathematical Model: Linear
Certification: RoHS, ISO: 9001, CE
Condition: New
Customized: Customized
Samples:
US$ 15/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ISO 4-20mA-E
Input
4-20mA
Output
4-20mA
High Precision Measuring Range
0.1,0.2
Nonlinearity
<0.1%
Isolation Voltage
3000VDC
Isolation Mothod
Electromagnetic Isolation
Package
SIP12pin or DIN3 or DIN35 Rail-Mounted
Industrial Operaing Temperature
-45~+85 Centigrade
Lead Time
3-4working Days
Warranty
2 Years
Shiping Way
DHL , FedEx ,etc
Customzed
Support
Keywords 1
Signal Conditioning
Keywords 2
Isolator
Keyword 3
Isolation Amplifier
Transport Package
Color Box
Specification
10g/pc
Trademark
SUNYUAN SZ
Origin
Shenzhen, China
HS Code
8543709200
Production Capacity
5000000/Month

Product Description

Two-wire passive 4-20mA current loop isolation conditioner i/o module 


Features:
No external power supply required, two-wire signal loop powered output mode.
Active 4-20mA signal acquisition, volt. (5-32V) extra-wide range input.
High precision within 4-20mA measuring range (0.1, 0.2).
4-20mA signal transmission with high linearity(non-linearity error <0.1%).
Active 4-20mA signal acquisition input, 3KV isolation between input and output.
Active signal input, the output can control the active load in current loop.
SIP 12Pin small size, UL94V-0standard fire-retardant package.
Industrial operating temp.: - 45º C~ + 85º C.


Applications:
Two-wire active load signal matching and controlling.
PLC, DCS site analog signal isolation and acquisition.
Ground wire current loop isolation and interference.
The matching between sensor signals and analog data input and output terminals.
Sensor 4-20mA signal isolated acquisition, conditioning and transmission.
Analog signal data isolated acquisition and long-distance transmission.
Electric meters and instruments, medical equipments.
SIP 12pin Two Wire Passive 4-20mA Signal Conditioning

Specification:

Item 4-20mA Loop Powered Isolated Signal Conditioner Module
Model No. ISO 4-20mA-F
Input 4-20mA
Output 4-20mA
Power supply Powered by current loop
Isolation voltage 3KVDC isolation between input and output 
Package Sip 12
Optional package type DIN rail mounted type
Dimensions and pin function description and Diagram of wiring:
SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
SIP 12pin Two Wire Passive 4-20mA Signal Conditioning


Pakcaging pictures as bellow:
(SIP pin packaging ,                                     DIN3 rail-mounted packaging ,                     DIN35 Rail-mounted packaging)
SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
SIP 12pin Two Wire Passive 4-20mA Signal Conditioning

SIP 12pin Two Wire Passive 4-20mA Signal Conditioning
For more information, please feel free to contact us:
Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download: 
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA 
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series 
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F 
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA 

Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download: 
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC  
2,
 ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC 
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC 
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter

8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter 
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter 
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring 
13,ISO F-P-O  Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier 
16.Large current output type high precision signal transmitter



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now