PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition

Product Details
Customization: Available
Input: DC Current or Voltage
Output: RS232 or RS485
Still deciding? Get samples of US$ 189/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
27
Year of Establishment
2002-09-10
  • PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
  • PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
  • PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
  • PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
  • PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
  • PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
Find Similar Products

Basic Info.

Model NO.
ISO AD16
Power Supply
24VDC
Amount of Channle
4--16 Channel
Precision
24bit
Transport Package
35mm DIN Rail-Mounted
Specification
ISO9001: 2008, CE, ROHS
Trademark
YUAN
Origin
Shenzhen
Production Capacity
50000PCS/Year

Product Description

Pt100 0-75mV,0-2.5v to RS232 Data Acquisition Converter

Features:
Low cost, small size
Analog signal acquisition, isolated conversion RS-485/232 output
Measuring accuracy > 0.05%, nonlinearity <0.05%
RS-485/232 output, can be remotely reconfigured for modules accuracy
Input signal/Output signal 3000VDC
Wide power supply range: 8 ~ 50VDC
High reliability, convenient programming, easy installation and wring
User can set module address and baud rate, etc.

Applications:
Signal testing/ monitoring /control
Intelligent building control, security and engineering applications
RS-232/485 industrial automation control system
Industrial fields signal isolation and long-terms transmission
Debugging and controlling of equipment operation
Acquisition and record of industrial field data
Support Modbus RTU communication protocol
Development of medical and industrial products
Current/voltage signal

Product introduction:
ISO AD series converter achieve the signal isolated acquisition between sensor and the host and can be used for a variety of sensors. ISO AD series of products can be used in industrial automation RS-232/485 bus system, 4-20mA / 0-5V signal measurement, monitoring and control, small-signal measurement, and industrial-site signal isolation and long-term transmission and so on.
Products include power supply isolation, signal isolation, linearization, A/D conversion and RS-485 serial communication circuit module. Each serial port can connect maximum 256 PCS of ISOAD series modules, means of communication using character communication protocol or MODBUS RTU communication protocol. Its instruction set compatible with the ADAM modules, the baud rate is set by the user, with other manufacturers control module hanging in the same RS-485 bus, to facilitate host programming.

ISO AD series of products are based on single chip of intelligent monitoring and control systems, all the user sets such as the calibration value, address, baud rate, data format, checksum status and other configuration information is stored in nonvolatile memory EEPROM inside.
ISODA series of products according to industry standard design, manufacture, signal output / communication interface isolation, can withstand 3000VDC isolation voltage, anti-interference ability, high reliability. Operating temperature range: - 45 ~ +80.

Model selection
ISOAD16 U(A) -

Vin/Iin
U1: 0-5V A1: 0-1mA
U2: 0-10V A2: 0-10mA
U3: 0-75mV A3: 0-20mA
U4: 0-2.5V A4: 4-20mA
U5: 0-± 5V A5: 0-± 1mA
U6: 0-± 10V A6: 0-± 10mA
U7: 0-± 100mV A7: 0-± 20mA
U8: Customized A8: Customized

Communication interface
485: Output is RS-485 interface
232: Output is RS-232 interface
item no ISO AD16

PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
PT100 0-75mv, 0-2.5V, 4-20mA, 0-10V to RS232 RS485 Modbus Protocol Analog Input Data Acquisition
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier