• 0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
  • 0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
  • 0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
  • 0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
  • 0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
  • 0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)

0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)

Input: 0-2.5V,0-5V,0-10V,0-20mA,4-20mA,0-&etc
Output: RS232,RS485
Power Supply: 8-50VDC
Accuracy: 0.05%
Band Width: -3 dB 10 Hz
Switching Rate: 10 Sps
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ISO 4021 U(A)
Common Mode Restraint
120 dB
Normal Mode Restraint
60 dB
Input Port Protection
Over-Voltage/Over Current Protection
Response Time
100 Ms Max
Transport Package
35mm DIN Rail-Mounted Type
Specification
ISO9001: 2008, CE, ROHS
Trademark
SUNYUANSZ
Origin
Shenzhen
Production Capacity
50000PCS/Year

Product Description


   0-5V /4-20mA to RS485/RS232 A-D Converter Data Acquisition ISO 4021  U(A)
Model selection
:

ISO 4021  U(A) -  
 
U/A: Input voltage or current signal                   Output: communication interface
U1:0-5V           A1:0-1mA                         232/485: Output is RS-232 or RS-485 interface
U2:0-10V          A2:0-10mA                
U3:0-75mV         A3:0-20mA          
U4:0-2.5V          A4:4-20mA                         
U5:0-±5V          A5:0-±1mA                         
U6:0-±10V         A6:0-±10mA                         
U7:0-±100mV       A7:0-±20mA
U8:Customized     A8:Customized
         
 
Remark:When the communication interface is RS232, it should connect with RXD and TXD port; when the communication interface is RS485, it should connect with DATA+ and DATA- Port. RS232 and RS485 can't work at the same time.
E.g.
1: ISO 4021 A4-232/485   Means 4-20ma signal input, output is RS232 or RS485
2: ISO 4021 U1-232/485   Means 0-5V signal input, output is RS232 or RS485
3: ISO 4021 U5-232/485   Means 0-±5V signal input, output is RS485 or RS232
 
 
ISO 4021 A-D Converter General Parameters:
(typical @ +25ºC,Vs is 24VDC)
Input:              Voltage / Current
Accuracy:           0.05%
Input imbalance:     ±0.1 uA/ºC
Temperature Drift:  ±15 ppm/ºC (±30 ppm/ºC, max)
Input Resistance:   50Ω (4-20mA/0-20mA/0-±20mA current input) 
                   100Ω (0-10mA/0-±10mA current input)
                  1KΩ (0-1mA/0-±1mA current input)
                  >1MΩ(voltage input)        
Band width:       -3 dB 10 Hz
Switching rate:     10 Sps
Common mode restraint(CMR):  120 dB(1kΩ Source Imbalance @ 50/60 Hz)
Normal mode restraint(NMR):   60 dB (1kΩ Source Imbalance @ 50/60 Hz)
Input Port protection:           over-voltage/over current protection
Communications:   protocol  RS-485 or RS-232   ASCII protocol and MODBUS RTU communication protocol
                  Baud rate(300,600,1200,2400,4800,9600,19200,38400bps)software configuration
address(00H~FFH)software configuration
Response Time:100 ms max
Operation Power Supply:    +8 ~ 50 VDC wide power supply range, internal anti-reverse & over-voltage protection               
watt consumption:    < 1W
Operation Temperature:    - 45 ~ +80ºC         
Operation Humidity:   10 ~ 90% (non-condensing)
Storage Temperature:   - 45 ~ +80ºC               
Storage Humidity:   10 ~ 95% (non-condensing)                                     
Isolation withstand voltage:   between input and output:  3KVDC,1 minute,stray current 1mA
                           Output and power are common-ground.
Endure Impact Voltage:    3KVAC, 1.2/50us(peak value)
Dimensions:   83 mm  x  37 mm  x  51mm
Weight:        72g

Choice for Example as bellow :
Model for example Input signal output interface
IS0 4021 A4-485 4-20mA RS-485 interface
ISO 4021 U1-232 0-5V RS-232 interface

0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
0-5V /4-20mA to RS485/RS232 a-D Converter Data Acquisition ISO 4021 U (A)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now