• 4~20mA Loop Current Active Load Isolation Controller
  • 4~20mA Loop Current Active Load Isolation Controller
  • 4~20mA Loop Current Active Load Isolation Controller
  • 4~20mA Loop Current Active Load Isolation Controller

4~20mA Loop Current Active Load Isolation Controller

Task: Adjust
Structure: Open-Loop
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: RoHS, ISO: 9001, CE
Samples:
US$ 18.50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ISO 4~20mA-E
Condition
New
Customized
Customized
Input Siganl
4-20mA Signal
Output Siganl
4-20mA Signal
Accuracy
Grade 0.1, 0.2
Auxiliary Power
No
Hysteresis Error
Less Than 0.5%
Isolation Voltage
3000V
Transport Package
Plastic Tube and Gift Box
Specification
SIP 12Pin, DIN3, DIN35
Trademark
Sunyuan or OEM
Origin
Guangdong, China
Production Capacity
5000PCS/Month

Product Description

4~20mA Loop Current Active Load Isolation Controller
ISO 4-20mA-E Series
Regulating and Controlling Active Load in Current Loop from PLC/DCS through Active Signal
 
Introduction:
SUNYUAN SIP12 Package Two-wire 4-20mA Signal Isolated Conditioning and Controlling IC: ISO4-20mA-E is akind of two-wire active sensor (4-20mA) signal isolated conditioner, it belongs to ISO4-20mA series products. It can converter active 4-20mA current signal into isolated passive controlling signal to control the two-wire powered (explosion-prevention method) 4-20mA current loop. The module achieves the matching between sensor signals acquisition and active load from analog input end, which effectively solves problems on the conflict between the active 4-20mA current signal and power supply of two-wire current loop input end.

ISO 4-20mA-E series module employed high-efficiency stealing electricity technology which makes the ic can operate without independent power supply. And the two-wire loop powered output method used which largely reduces the costs for customers in installation. Inside the IC, there are current signal modulation circuit, magnetoelectric isolation transform circuit and signal reduction demodulation circuit,etc. The low input equivalent resistance makes the voltage value of the current signal from the sensor output loop arrive at 5~32VDC to realize the long-distance, non-distortion
transmission of signals without external power supply.

The output of ISO4-20mA-E Module is designed on the basis of the two-wire powered loop circuit of the 24VDC and sampling resistance (two-wire meter) which are parallelly connected, the output also matches well with the analog input terminals of the industrial equipments like analog input interface board (host machine), PLC, DCS, and other instruments and meters,etc. The module is convenient to use to achieve the isolation, transmission and acquisition of two-wire 4-20mA signal by add an external 10KΩ multi-turn potentiometer to do adjustment and meets the requirements that operating in industrial field wide temperature, humidity, vibration, etc adverse operation conditions.
 
4~20mA Loop Current Active Load Isolation Controller
SIP 12Pin
4~20mA Loop Current Active Load Isolation Controller
DIN3 Type
4~20mA Loop Current Active Load Isolation Controller
DIN35 Type

All products have passed CE & RoHS certification
The factory has obtained GB / T19001-2016 / ISO 9001:2015

Features:

1. No external power supply required, two-wire signal loop powered output mode.
2. Active 4-20mA signal acquisition, volt. (5-32V) extra-wide range input.
3. High precision within 4-20mA measuring range (0.1, 0.2). 4-20mA signal transmission with high linearity(non-linearity error <0.1%).
4. Active 4-20mA signal acquisition input, 3KV isolation between input and output.
5. Active signal input, the output can control the active load in current loop.
6. SIP 12Pin small size, UL94V-0standard fire-retardant package. 
7. Industrial operating temp. : - 45ºC ~ + 85ºC.

Application:
1. Two-wire active load signal matching and controlling.
2. PLC, DCS site analog signal isolation and acquisition.
3. Ground wire current loop isolation and interference.
4.  The matching between sensor signals and analog data input and output terminals.
5. Sensor 4-20mA signal isolated acquisition, conditioning and transmission.
6. Analog signal data isolated acquisition and long-distance transmission.
7. Electric meters and instruments, medical equipments.