0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output

Product Details
Customization: Available
Task: Adjust
Mathematical Model: Linear
Manufacturer/Factory & Trading Company
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
27
Year of Establishment
2002-09-10
  • 0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output
  • 0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output
  • 0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output
  • 0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output
  • 0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output
  • 0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output
Find Similar Products

Basic Info.

Model NO.
DIN2X2 ISOEM 2
Function
Protection
Certification
ISO: 9001
Condition
New
Customized
Customized
Material
ABS
Transport Package
Plastic Tube and Gift Box
Trademark
32x9x6cm
Origin
Shenzhen, Guangdong, China
HS Code
9026900000
Production Capacity
50000PCS Per Month

Product Description

2-in 2-out 4-20mA to 0-5V 0-10V Signal Converter

Features of 0-5V to 0-20mA/4-20mA Transmitter/Converter
>> Efficiency grade: 0.2, 0.5
>> The modules already been calibrated before ex-factory, user can use it directly.
>> Non-linearity <0.2%, no zero and gain adjustment.
>> Isolation among signal input1/ input 2/ output1/output 2/Auxiliary power
>> Auxiliary power supply: 5VDC, 12VDC, 24VDC single power supply
>> Two-channel input and output can be uniform or different DC current or voltage signal.
>> 0-75mV//0-5V/0-± 100mV/0-± 10V etc voltage signal and 0-10mA/0-± 20mA/4-20mA etc current signal isolation, amplification and conversion
>> Industrial operating temperature: - 45º C ~ + 85º C

0-5V/4-20mA/0-10V Converter Applications:
>> Multi-channel sensor signal display and control.
>> Industrial field signal isolation, conversion, amplification and long-term transmission.
>> Interference rejection of 2X2 4-20mA signal ground.
>> Data acquisition, interference rejection of analog signal ground.
>> Electric power control, medical equipment isolation safety bar
>> Instrument and sensor signal receiving and detection
>> 4-20mA/0-5V etc signal isolation, distribution and conversion.
>> Industrial field analog and digital signal monitoring and control

0-5V/4-20mA/0-10V Converter Description:
Sunyuan DIN 2X2 ISO EM Series Analog Signal Isolation Amplifier/Transmitter is a kind of hybrid integrated modules which convert multi-channel analog voltage or current signals from the sensor, PLC into corresponding standard analog signals with the same accuracy and linearity. Inside the module, it integrates two set of ISO EM series high isolation analog signal isolation amplifier IC and adopts magnetoelectric coupling with low cost, which mainly used in the field with no special requirements for EMC (magnetoelectric interference). By using input and output side creepage distance and inner isolation design, the module realizes the isolation among signal input1, input 2, output 1, output2 and auxiliary power.

0-5V/ 0-10V to 0-20mA / 4-20mA Transmitter/Converter Technical Parameter:
Accuracy ---------- 0.1%, 0.2%, 0.5%
Auxiliary Power---------- DC5V, 12V, 24V, ± 10%
Operating Temp. ---------- -40 ~ +85º C
Working Humidity---------- 10 ~ 90% (No dew)
Storage Temp. ---------- -55 ~ +108º C
Storage Humidity---------- 10 ~ 95% (No dew)
Isolation ----------signal input/output/Auxiliary power
Insulation Resistance ---------- ≥ 20MΩ
2500VDC, 1 minute, leakage current 1mA
Impact Resistance Volt. ---------- 3KV, 1.2/50us(peak value)
Input Specification    Output Specification
Input Input Impedance Power Consumption Input Overload Capacity Output Output Overload Capacity
 
Response time
0-5V ≥300KΩ Volt. Output
< 0.8W


Current output
<2W
2.0 times rated:
Continuous
4-20mA Load resistance*
≤350Ω
≤1mS
0-10V 0-20mA
0-1mA TYP:250Ω
or
Customized 
1.5 times rated:
Continuous 
3.0 times rated:1S
 
0-10mA 0-5V ≥2KΩ
0-20mA 0-10V
4-20mA 1-5V
0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output


0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output0-5V to 4-20mA Signal Isolation Converter 2 Channel Input 2 Channel Output
For more information, please feel free to contact us:
Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download: 
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA 
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series 
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F 
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA 

Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download: 
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC  
2,
 ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC 
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC 
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter

8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter 
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter 
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring 
13,ISO F-P-O  Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier 
16.Large current output type high precision signal transmitter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier