• DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
  • DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
  • DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
  • DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
  • DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
  • DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components

DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components

Type: Signal Converter
Measuring Medium: Current/ Voltage
Display Type: No
Site Display: Not Site Display
Accuracy: 0.2
IP Rating: No
Samples:
US$ 19/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DIN3 ISOEM U(A)-P-O Series
Certification
CE/RoHS/FCC
Customized
Customized
Input
0-75mv/0-2.5V/0-5V/0-10V, etc
Output
0-75mv/0-2.5V/0-5V/0-10V, etc
Power Supply
5VDC/12VDC/15VDC/24VDC
Temperature Range
-45~+85 Centigrade
Isolation Method
Magnetoelectric Isolation
Isolation Voltage
3000VDC
Package
SIP 12pin or DIN3 or DIN35 Rail-Mounted for Option
Certificates
CE RoHS ISO9001
Accuracy Level
0.1 Level, 0.2 Level
Lead Time
3-4working Days
Warranty
2 Years
Shipping Way
DHL /FedEx etc
Delivery Time
3-5 Working Days
Payment Way
Paypal ,T/T, Wester Union
Keywords
Signal Converter, Signal Transmtiter
Transport Package
Box
Specification
10g/pc
Trademark
SUNYUAN SZ
Origin
Shenzhen, China
HS Code
8543709200
Production Capacity
5000000/Month

Product Description

DIN3 Rail 0-5V/0-10V/4-20mA/0-20mA Current Voltage (I/V, I/I,V/I, V/V) Signal Isolation Amplifier Magneto-electric Isolation Transmitter/Converter


General characteristics:
>> Efficiency Grade:0.1/0.2
>> High precision, error and nonlinearity < 0.1%
>> 0-5V/0-10V/1-5V/0-+/-5V/0-+/-10V/0-10mA/0-20mA/4-20mA international standard current signal input and output
>> Three port isolation:Input/output/power supply isolation voltage can reach 3000VDC.
>> Temperature Range:-25~70 deg.C
>> Standard DIN Rail Mounting,super slim (12.5mm),low cost.

Applications:
>> DC current/voltage signal isolated/transfer/amplifier
>> Equipment and sensor signal acquisition
>> 4-20mA signal isolation and transfer
>> Ground-loop elimination
>> Electric power,medical instrument isolated safe bar.
>> No distortion in long distance signal

Max. Rated Value
(If the product operates in the max. rated vale in the long-term, may affect the durability, if exceed the max. values, may cause unrepairable damage.)

Continuous Isolation Voltage 3KVDC/rms
Power supply Volt. Input Range: ±25%Vdd
Operating Temperature - 45ºC ~ + 85ºC
Wielding Temperature (<10s)>
Voltage Signal Output Min. Load 2KΩ
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components

General Parameters

Parameters
Test Conditions Min. Typical Value Max. Unit
Isolation voltage AC,50Hz,1min   3000   V(rms)
Gain


 
    1   V/V
Gain temp. drift     35   ppm/ºC
Non-linearity     0.1 0.2 %FSR
Signal Input Voltage   0   15 V
Current   0   30 mA
Input offset voltage     2 5 mV
Input impedence Voltage     1   M
Current     50 250 Ω
Signal output Voltage   -10   10 V
Current   -20   20 mA
Load capacity Voltage Vout=10V   2  
Current   0 350
50
650 Ω
Frequency response -3DB
 
  1   KHz
Signal output ripple No filtering   10 20 mVRMS
Signal voltage temp. drift       0.2 mV/ºC
Auxiliary power Voltage User-defined 3.3 12 24 VDC
Consumption     0.5 1 W
Operating ambient temp.   -45   85 ºC
Storage Temp.   -55   105 ºC

Note: For the product with special requirements on the load capacity of voltage and current signal, please notify us.
 

Output
Output load capacity Response time
4-20mA ≤350Ω
(If the 650Ω load is required, please notify us)
<1ms<>
0-±20mA
 
0-±5V > 2KΩ
0-±10V
1-5V
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components

Step Two : We have 3 different Installation methods , as bellow shows, you can confirm with us which one installation method suitable for you ?

 
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
Step three : the final model number confirmation:
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components
Pin description for the 3 different installation methods for customers reference:
DIN3 Isoem U (A) -P-O 4-20mA to 0-10V Signal Converter Electronic Components

Other products:
Commonly used two-wire passive isolation amplifier, isolation transmitter IC, Sunyuan product technical information download: 
1,4-20mA (0-20mA) Current Loop Isolator IC: ISOS 4-20mA 
2,4-20mA two-wire passive I/V conversion isolation transmitter IC: ISO 4-20mA-O series 
3,4-20mA isolation controller (active signal PLC current loop active load) IC: ISO 4-20mA-E
4,Two-wire passive sensor 4-20mA loop isolation distributor IC: ISO 4-20mA-F 
5,Two-wire voltage signal power distribution isolation transmitter IC: ISO V-4-20mA 

Commonly used active type (external auxiliary power supply required) isolation amplifier transmitter IC, product selection application data download: 
1,ISO mV series: millivolt-level analog small signal dedicated isolation amplifier IC  
2,
 ISO EM U(A)-P-O-T Series: Zero-point, gain-adjustable analog isolation amplifier isolation transmitter
3, ISO EM A(U)-P-O-S Series: Input Distribution Isolation Transmitter IC 
4, ISO EM-U(A)-P-O-O Series: Analog Input Isolation Transmitter with 1 to 2 Output Low Cost Small Size IC mounted Package 5, ISO EM A-P-O Series: 0-±10V Bilateral DC (Voltage/Current) Signal Isolation Amplifier Isolation Transmitter IC 
6, DIN3 ISOEM U-P-O(A-P-O) Series: Single DIN35 rail mounting packaging low cost small volume isolation transmitter
7,DIN 1X2 ISOEM U(A)-P-O Series: one input and two output DIN35 rail mounting packaging isolation transmitter

8,DIN 2X1 C-P-O Series: 2 input and 1 output analog average isolation transmitter 
9,DIN 2X2 ISOEM U(A)-P-O Series: two in two out DIN35 rail mounting isolation transmitter
10,DIN 1X3 ISOEM U(A)-P-O Series:one in three out DIN35 Rail mounting isolation transmitter 
11,DIN ISO AC Series: Passive two-wire AC to DC signal isolation transmitter
12,ISO EMH 4-20mA Series: High isolation barrier for track voltage monitoring 
13,ISO F-P-O  Series: Frequency Signal (FV/FI Conversion) Isolated Converter IC
14,ISO U(A)-P-F Series: Analog Signal to Frequency Pulse Signal (V/F) Isolated Transmitter IC
15,ISO EM RMS-P-O Series: Analog True RMS (RMS) Signal Isolation Transmitter Isolation Amplifier 
16.Large current output type high precision signal transmitter

 
 

























 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now