• 6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series
  • 6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series
  • 6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series
  • 6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series
  • 6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series
  • 6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series

6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series

Input: 5V/9V/12V/24VDC,2:1 Wide Voltage Range
Output1: 50V/100V/110V/150V/200V/300VDC
Power: 1W~5W
Isolation Voltage: 6000VDC
Weight: 10g
Features: Low Cost,Small Size
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GRE DC DC Covnerter Series
Certificates
Ce RoHS ISO9001:2000/2008
Export Market
Global
Transport Package
SIP12, SIP
Specification
CE/RoHS/ISO9001: 2000/2008 Certified
Trademark
Sunyuan
Origin
China
Production Capacity
50, 000PCS/Quater

Product Description

 6KVD Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc equipments : GRE Series

Product features:


1. Low cost and small size SIP 12PIN packaging meets UL94V-0 standard of flame retardant packaging.
2.There is 6KVD isolation between the input and output of this module,And also 6KV isolation between the output loop one and loop two.
3.2: 1 DC wide voltage input range, isolated regulated DC high voltage output . 
4.Output voltage: 50VDC ~ 400VDC voltage value is for you optional. 
5.Output power: 1W ~ 5W optional .
6. Two-way high voltage output circuits have self-recovery overload
short-circuit protection. 
7.Working under natural air cooling conditions, needn't any cooling 
device, conversion efficiency: 60% ~ 80% .
8.Industrial temperature range: -40 ~ + 85 ºC .

Product description:

SunYuan the newly developed GRE series of low cost, small size, wide voltage input isolation and regulated dual loop output high voltage module power is an high voltage DC-DC converter in the leading position of the field. This item can operate safely in a wide range of unstable power supply voltage input environment, and can generate isolated and regulated DC high voltage dual loop output through the internal adjustment circuit of the module. GRE series new products adopt SIP 12Pin (single row 12 feet) small size module design, low cost integrated technical solutions make the product have higher DC/DC conversion efficiency and self-recovery overload short circuit protection voltage regulator output function. The wide creepage distance of product's internal and new isolation technology design solution make this high voltage module power supply with 6KVDC isolation between the input and output. And 6KVDC isolation between output loop 1 and loop 2,this technology can effectively isolate the influence of the common mode interference signal from the primary device on the control system,also can effectively isolate the ground loop circulation crosstalk between the primary and secondary ends of the power supply, it can effectively protect the safety threats of equipment and operators by the high voltage potential difference between different ground terminal in power equipment and medical instruments. Products are widely used in power equipment, medical instruments, laser power supplies, ultrasonic instruments, communication facilities, petrochemical industry and mine explosion-proof equipment etc.
6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series

SunYuan the newest product GRE series dc dc converter with low cost, small volume, wide voltage input isolation high voltage dual loop output which is widely used in the following instruments and equipments: nuclear testing instruments, electronic anesthesia machines, medical blood analysis, medical X-ray, medical CT, medical Imaging PET and MRI bone density testing, PM2.5 environmental monitoring, 3D printing, automatic test equipment, capacitor charge and discharge, chromatograph, mass spectrometer, carbon dioxide laser, cathode ray tube, photomultiplier tube, insulation breakdown test, electron beam exposure , Capillary gel electrophoresis, protein extraction, DNA sequencing, electrostatic chuck, display driver, flight simulation experiment, micro-channel plate, electrostatic coating, electrostatic flocking, electrostatic precipitator, oil fume and air purification, electrostatic spray (spraying, painting ), Image intensifier, industrial color printing, luggage inspection, food inspection, PCB inspection, nondestructive inspection, thickness gauge, focused ion beam microscope for photomask repair, ion implantation, magnetron, klystron, neutron generator , Spectrometer, agricultural demisting and dew production increase ...At present, Sunyuan Technology Co., Ltd. is efforts to continuously improve the isolated high-voltage power supply product line to meet the growing demands of power, medical, scientific research and other industries.



Model number and definition:    
6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series

GRExxxxS Series Model Number Example:  (The bellow data is the detection value of the product after 8 hours of continuous full load aging)
Model Number Input volt Vin(VDC) Output Volt/Current No-load power consumption(mW) Full load efficiency(%)
Nominal value  Vin(VDC) Range Vin(VDC) Output current
Full load (mA)
Output Volt Vout(VDC )
GRE05050050S-1W 5 4.5~9 10/10 50/50 350 61
GRE05100100S-1W 5/5 100/100 62
GRE05150150S-1W 3.4/3.4 150/150 60
GRE05200200S-1W 2.5/2.5 200/200 65
GRE05250250S-1W 2/2 250/250 63
GRE05300300S-1W 1.67/1.67 300/300 65
GRE05400400S-1W 1.25/1.25 400/400 64
GRE05050050S-2W 5V 4.5~9 20/20 50/50 350 60
GRE05100100S-2W 10/10 100/100 61
GRE05150150S-2W 6.7/6.7 150/150 63
GRE05200200S-2W 5/5 200/200 62
GRE05250250S-2W 4/4 250/250 64
GRE05300300S-2W 3.4/3.4 300/300 62
GRE05400400S-2W 2.5/2.5 400/400 64
GRE12050050S-3W 12 9~18 30/30 50/50 350 73
GRE12100100S-3W 15/15 100/100 76
GRE12150150S-3W 10/10 150/150 77
GRE12200200S-3W 7.5/7.5 200/200 75
GRE12250250S-3W 6/6 250/250 79
GRE12300300S-3W 5/5 300/300 80
GRE12400400S-3W 3.75/3.75 400/400 75
GRE12050050S-4W 12 9~18 40/40 50/50 350 72
GRE12100100S-4W 20/20 100/100 73
GRE12150150S-4W 13.4/13.4 150/150 75
GRE12200200S-4W 10/10 200/200 77
GRE12250250S-4W 8/8 250/250 76
GRE12300300S-4W 6.7/6.7 300/300 80
GRE12400400S-4W 5/5 400/400 78
GRE24050050S-5W 24 18~28 50/50 50/50 350 72
GRE24100100S-5W 25/25 100/100 73
GRE24150150S-5W 16.7/16.7 150/150 75
GRE24200200S-5W 12.5/12.5 200/200 77
GRE24250250S-5W 10/10 250/250 76
GRE24300300S-5W 8.4/8.4 300/300 78
GRE12400400S-5W 6.25/6.25 400/400 75
Remarks: If you need other non-standard output voltage parameters, please contact with Shunyuan Technology Co., Ltd.

Product technical parameters and characteristics:
Project Working Condition Min Typical value Max Unit
Output voltage accuracy 1%-100% load range   ±2   %
Load Adjustment rate Nominal voltage input, load from 10% to 100%   ±1   %
Linear adjustment rate Input voltage range, full load   ±1   %
Ripple & Noise 20MHz bandwidth, parallel line test method   ±1   %
Switch frequency Nominal voltage input, full load   200 400 KHz
Temperature Coefficient Nominal voltage input, full load   0.02   %/ºC
stability After half an hour of booting, the hourly rate of change   0.001   %/Hr
Output short circuit protection Output short circuit Sustainable,Self-recovery
Isolation withstand voltage Leakage current 1mA, time 60s   6000   VDC
Pin soldering temperature Welding point ≥1mm from the shell, 10s   +300   ºC
Insulation resistance Input/Output,500VDC,25ºC,70%RH   1000  
Working temperature   -40   +85 ºC
storage temperature   -55   +105 ºC
Storage humidity No condensation     95 %RH
cooling method   Natural air cooling
Hot swap   Don't support
MTBF MIL-HDBK-217F@25ºC 1000     KHours
Shell material   Plastic shell-PVC flame retardant material
Packaging Size Length * width * height 33.0 x 10.5 x 15.5 mm
Weight     10   g


Safety precautions and conventional methods of product high voltage isolation test:
1,As show above picture 1: Set the rated high voltage value according to the product isolation voltage specifications. Please pay attention to personal safety when testing and beware of electric shock!
Test condition: room temperature TA = 25 ºC, humidity <75%
2,The operator of the withstand voltage test must wear rubber insulation (insulation voltage> 10KV) gloves, and place insulation pads on the workbench and seat floor to prevent high voltage electric shock.
3,The pressure tester instrument must be reliably grounded and cannot be detected in a high temperature, humid and dusty environment.
4,When the withstand voltage tester is connected to the test object, it cannot be operated with power on, and the output voltage value of the high voltage tester must be zero.
5,When the instrument is in the startup state or the high voltage is not released, it must not touch the measured object, test line or high voltage test line and test fixture.
6,The product test method like above picture 1: all pins of the input and output terminals are connected in parallel, and the test is performed for 1 minute according to the isolation voltage value given by the product.
7,According to the test standard for withstand voltage, the withstand voltage value is gradually adjusted upward from 0. When the withstand voltage value is adjusted to the set maximum withstand voltage and maintained at the highest withstand value for one minute.
8,The pressure test itself is a destructive test. The fewer times the product should be done, the better. If the customer needs multiple tests, the general requirements are: the first measurement is based on the voltage value of the specification, and the voltage value should be reduced accordingly for each subsequent test, otherwise the product performance will be reduced or directly damaged.


6kvd Double Loop Isolated Output High Voltage DC/DC Power Module for Medical Blood Analysis and Nuclear Testing Instruments etc Equipments: Gre Series

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now